UV-VIS SPECTROPHOTOMETER
MAKE DINESH SCIENTIFIC
DESCRIPTION
With a wavelength range of 190–1100 nm and a spectral bandwidth of 0.5 to 4 nm, the Microprocessor UV/VIS Spectrophotometer (Double Beam) 2 CELL HOLDER that is being offered has a working mode that is classified as Basic/Quantitative/Wavelength Scan/DNA Protein Test/Kinetics (T,A,C). A double beam (1200 lines/mm Grating) based optical system, three scanning speed options (Fast, Medium, and Slow), a photometric range of -4 to 4 Abs 0 to 220 %T, and wavelength accuracy of +/- 0.1 nm in U.V. range are further features of the system. Aside from wavelength reproducibility of 0.1 nm other standard features of the system include software CD, USB cable, and operation manual availability.
An advanced scientific tool for examining the properties of substances’ absorption in the ultraviolet region of the electromagnetic spectrum is a UV spectrophotometer. These devices, which operate in the 190–1100 nanometer wavelength range, use a monochromatic and a light source usually a stable deuterium lamp to isolate particular UV light wavelengths. The sample is exposed to the light beam while housed in a quartz or glass cuvette inside the sample compartment. A detector typically a photomultiplier tube or diode arraymeasures the transmitted or absorbed light. For improved accuracy, the spectrophotometer can be designed with a single beam or two beams, the latter of which compares the beams used for the sample and the reference. Temperature-controlled sample compartments and pathlength adjustment for advanced features.
FEATURES:
WAVELENGTH RANGE:
- The ultraviolet region of the electromagnetic spectrum, which is normally between 190 and 1100 nanometers, is covered by UV spectrophotometers. Certain instruments may have longer ranges, extending into the visible and near-UV spectrums.
SINGLE OR DOUBLE BEAM DESIGN:
- UV spectrophotometers come in single or dual beam configurations. Because they compare the sample and reference beams, double beam instruments are more widely used and offer higher accuracy.
LIGHT SOURCE:
- For the UV spectrum, deuterium lamps are frequently used because they offer a steady and continuous light source. Additional light sources present in some instruments to provide a wider range of wavelengths.
MONOCHROMATOR:
- A monochromator is a device that selects a particular light wavelength. Monochromators with grating or prism bases are widely used and offer excellent wavelength selection flexibility and resolution.
SAMPLE COMPARTMENT:
- The cuvettes containing the sample and reference solutions are kept in the sample compartment. Multiple sample positions available on certain instruments for high-throughput analysis.
TECHNICAL DETAILS:
MODEL | DS-SPM-1100 |
Measurement Wavelength Range | Covers a range of 190 – 1100 nm (when used as a standalone instrument without any additional accessories) |
Principle | UV/Vis spectrometer equipped with an automatic 6-cell changer. |
Optics | Utilizes a double-beam optical system |
Light Source | Includes a pre-aligned tungsten and deuterium bulb. |
Wavelength Accuracy | Provides wavelength accuracy within +/- 0.1 nm |
Photometric Accuracy at 1A | +/- 0.004 A |
Photometric Reproducibility (at 1A) | 0.001 A |
Baseline Flatness | Minimum ± 0.0005 A |
Noise Level at 500nm | Minimum 0.000016 A RMS |
Scan Speed | A scanning speed ranging from 1 to 6000 nm per minute. |
Working Mode | Run independently and on a PC using window-based program software. |
Monochromator | Double beam hollow graphic mattings 1200 lines/mm. |
Wavelength Reproducibility | wavelength reproducibility of 0.1 nm |
Band-pass/Bandwidth | Band-pass options in 4 steps ranging from 0.5 to 4 nm. |
Stray Radiation/Light | Ensures minimal stray radiation/light with a minimum of 0.02 %T. |
SOFTWARE | |
Standard Software | § Includes scan
§ Report builder § Arithmetic § Time drive § Wavelength programming § Concentration § Kinetics § Validation § As standard features of the software |
Local Accessories (Desirable) | With the system: PC i3 with 2 kVA UPS |
STANDARD ACCESSORIES:
- Quartz cuvette with 10mm path length, 6 numbers