SPECTROPHOTOMETER(DOUBLE BEAM)
Make Dinesh Scientific
DESCRIPTION
With a wavelength range of 190–1900 nm and a spectral bandwidth of 1 nm, the Microprocessor UV/VIS Spectrophotometer (Double Beam) 2 CELL HOLDER that is being offered has a working mode that is classified as Basic/Quantitative/Wavelength Scan/DNA Protein Test/Kinetics (T,A,C). A double beam (1200 lines/mm Grating) based optical system, three scanning speed options (Fast, Medium, and Slow), a photometric range of -4 to 4 Abs 0 to 220 %T, and wavelength accuracy of ±0.1 nm in U.V. range are further features of the system. Aside from wavelength reproducibility of less than ±0.1 nm, other standard features of the system include software CD, USB cable, and operation manual availability.
An advanced scientific tool for examining the properties of substances’ absorption in the ultraviolet region of the electromagnetic spectrum is a UV spectrophotometer. These devices, which operate in the 190–1900 nanometer wavelength range, use a monochromator and a light source—usually a stable deuterium lamp—to isolate particular UV light wavelengths. The sample is exposed to the light beam while housed in a quartz or glass cuvette inside the sample compartment. A detector—typically a photomultiplier tube or diode array—measures the transmitted or absorbed light. For improved accuracy, the spectrophotometer can be designed with a single beam or two beams, the latter of which compares the beams used for the sample and the reference. Temperature-controlled sample compartments and pathlength adjustment for advanced features
FEATURES:
WAVELENGTH RANGE:
- The ultraviolet region of the electromagnetic spectrum, which is normally between 190 and 1900 nanometers, is covered by UV spectrophotometers. Certain instruments longer ranges, extending into the visible and near-UV spectrums.
SINGLE OR DOUBLE BEAM DESIGN:
- UV spectrophotometers come in single or dual beam configurations. Because they compare the sample and reference beams, double beam instruments are more widely used and offer higher accuracy.
LIGHT SOURCE:
- For the UV spectrum, deuterium lamps are frequently used because they offer a steady and continuous light source. Additional light sources may be present in some instruments to provide a wider range of wavelengths.
MONOCHROMATOR:
- A monochromator is a device that selects a particular light wavelength. Monochromators with grating or prism bases are widely used and offer excellent wavelength selection flexibility and resolution.
DETECTOR:
- The intensity of transmitted or absorbed light is commonly measured using diode array detectors or photomultiplier tubes (PMTs).
SAMPLE COMPARTMENT:
- The cuvettes containing the sample and reference solutions are kept in the sample compartment. Multiple sample positions available on certain instruments for high-throughput analysis.
TECHNICAL DETAILS:
MODEL |
DS-SP-1900T |
Stray Light | <0.05%T at 340nm. |
Wavelength Range | 190-1075 nm. |
Wavelength Accuracy | +- 0.6nm. |
Display | Built-in 7-inch color touchscreen interface, tiltable. |
Photometric Range | 3.5A. |
Photometric Accuracy | +-0.005A at 1.0A. |
Photometric Repeatability | +-0.005A at 1.0 A. |
Noise | +-0.00050A at 260 and 500nm. |
Optical Design | Double Beam with reference/Blank and sample cuvette position separately. System 8-cell changer automatic. |
Spectral Bandwidth | 1nm/2.0 nm (Fixed bandwidth). |
Analysis Modes | · Absorbance mode
· Transmittance mode · Scanning mode · Live display mode · Kinetics available in standalone mode. |
Light Source | Single source for UV and Visible range covering 190 -1075nm. |
Light Source Detector | PMT Detector or Dual Silicon Photodiodes detector. |
Wavelength Repeatability | <+- 0.3 nm. |
Scanning Speed | 1400 nm/min. |
Data Interval | 0.1-4.0. |
Connectivity | USB/Ethernet/RS 232 port. |
Sample Holder | Sample compartment automatic 8-cell changer as standard feature/supply. |
INSTRUMENT FLEXIBILITY | |
Allows for future upgrades with the following options: | · Fiber Optic Probe.
· Peltier Thermostatted Cell Holder (20-60 deg. C). · Sipper Accessory. · PC Software for operation with PC. |
Photometric Drift/Stability | < 0.00075 A/hr. |
Baseline Flatness | +-0.004A. |
Pre-programmed Methods | Available for various qualitative and quantitative experiments of various types of biological samples. |
Custom Methods | Users can create custom methods tailored to their specific experiments. |
Software Capability | · Contaminant identification by Ratio on board.
· Display on a standard personal line computer screen and built-in touch screen. |
Supplier-provided Accessories | Monochrome single-function laser printer supplied with the Nanodrop. |
Connectivity | Cloud access for the built-in touch screen user interface. |
Included Components | · Necessary control kits
· Software systems · Start-up reagents, · Consumables supplied along with the instrument. |