REFRIGERATED CENTRIFUGE
MAKE DINESH SCIENTIFIC MODEL DS-RC-SAR
Product Description:
Being a client centric firm we are involved in offering an extensive range of Refrigerated Centrifuge For General and research Purpose . These are Specialist of Bench Top Centrifuges is very robust in appearance and make. Stepless speed regulator and transparent acrylic lid form a part of this Centrifuge. This can accommodate various capacities and types of rotors. In addition to this, we also assure to deliver a defect free range of our products in a fixed time frame. These products are available in different specifications so as to fulfill the varied needs of the customers. Our products are manufactured according to the customers’ requirements, as we are dedicated towards satisfying their requirements completely.
SCOPE OF APPLICATIONS:
- A refrigerated centrifuge is a good option for application where precise temperature control is critical, or a lower internal temperature is required during operation. A cooling system is included into a refrigerated centrifuge to lower and keep a preset temperature during operation.
- A centrifuge is a laboratory device that is used for the separation of fluids, gas or liquid, based on density. Separation is achieved by spinning a vessel containing material at high speed; the centrifugal force pushes heavier materials to the outside of the vessel.
TECHNICAL DATA:
PARAMETER | VALUE |
Type | Refrigerated Centrifuge |
Controller | · Microprocessor
· Controller · High Speed · Tabletop Refrigerated centrifuge |
Drive | Maintenance Free Induction drive motor |
Noise level | 55 dBA |
Speed | 100 RPM |
Rapid cool | Standstill and Rapid cooling program available. |
Temp. range | 10°C to 40°C, |
CFC free | CFC free refrigeration |
Cooling facility | Pre-cooling facility |
Run Time | · Run time 99 hrs. 59 min
· continuous run · start delay option · short run function |
Safety | · Automatic imbalance monitoring
· Self-diagnostic error messages · Motorized lid lock · Emergency lid lock releasing facility · Timer start after set speed has been reached. |
ROTOR | |
Fixed angle | · Fixed angle for 24 x 1.5/2.0ml
· Speed: 15,000 · 18,000 RPM |
Fixed angle | · Fixed angle for 6 x 50 ml conical bottom
· Speed: 14,500 RPM · 15ml tubes Adapters (6 No.) |
MTP Swing out Rotor | · MTP Swing out Rotor (capacity for 6 microtiter plates
· 2 Deep well plate & 4 PCR plate) · with Speed: 4500 rpm |
Swing out rotor | 6x50ml and 6x15ml capacity (≥ 4500 rpm) |
OPTIONAL | |
Rotor capability | · Angle Rotor 48x2ml (≥15000 to 18000rpm)
· Angle Rotor 6x30ml · (≥15000 to 18000 rpm), · Swing out rotor for multiple Micro-titer plate, ≥ 4700 rpm, Total Capacity: ≥ 1.6 Liter (4 x 400ml) |
Reviews