Specifications
Model No | DS-MC-AR |
Parameters | Values |
Purpose | Separating Serum from blood or for urine sedimentation |
Centrifuge Design | Bench Top |
Weight including Default Rotor in kg | 15 |
Auto cut off | Yes |
Timer provided | Yes |
Maximum RPM | 2800 |
Number of steps for RPM variation | 7 |
Incremental Steps of Variable RPM | 400 |
Type of Motor | Brushless (without carbons) |
Maximum Noise level whemn working at 1 meter distance in db | 45 |
Ambient operating Temperature range in Degree centigrade Celsius and humidity range | 0 to 50 degree centigrade and Relative humidity 15 to 90% |
Rotor imbalance diagnostics and automatic stop if required | Yes |
Facility to ensure that In case Machine is runing and lid is opened with manual lock by user , machine WILL stop | Yes |
Maximum Timer Set range | 60 minutes |
Timer settings Provided | interval of 10 secondsup to 1 minute and over 1 minute up to 60 minutes in interval of 1 minute |
Display | LCD |
Speed Controller | Microprocessor controlled pre programmed speed controller |
Speed Control Accuracy in case of set speed (Plus minus RPM ) | 50 |
Rotor configuration | Angle Rotor |
Rotor Feature with reference to Autoclavability | Autoclavable Rotor @ 121 Degree Celsus, |
Maximum Volume of the tube testable | Vaccutainers |
Rotor Size | 16 Vacuutainers |
Power supply | Single phase, 230 V 50 HZ AC Source |
Power concumption in watts | 600 |
Length of the Medical Centrifuge in mm | 370 |
Width of the Medical Centrifuge in mm | 325 |
Height of of the Medical Centrifuge in mm | 280 |
Length of Power cord in meters | 2 |
The Equipment WILL be installed and demonstrated before Acceptance installation and demonstration | No(No installation and demonstration required and consignee can install) |
Accessories | Spanner to tight or loose Nut of Rotor on Motor shaft head puller,spare rotor nuts ,fuse-2, Instruction Manual Book ,installation CD |
Assembly Material for manufacture of Medical Centrifuge | Consists of Die cast Aluminum, Aluminum sheet, Stainless Steel, CRC Steel,Plastic and Rubber |
Lid Material of Medical Centrifuge | C.R.C Steel Finish with Powder Coating or stove painting / ABS Plastic of injection moulding |
Body Material of Medical Centrifuge | C.R.C Steel Finish with Powder Coating or stove painting / ABS PLASTIC OF injection moulding |
Centrifuge Bowl material of Medical Centrifuge | 304 Quality Stainless Steel Moulded |
Material of Rotor | Aluminium, |