LYOPHILIZER
MAKE DINESH SCIENTIFIC MODEL DS-LYO-400
DESCRIPTION:
The method of extracting moisture from biological products without compromising their chemical structure, activity, or integrity is called freeze drying. Specifically, items that are often biological in origin their moisture removed using freeze drying technology without sacrificing any of their inherent qualities. In the fields of chemistry, pharmacy, and food preservation, freeze drying is the method of choice.
PERK OF FREEZING DRYING:
It is possible to freeze-dry heat-sensitive biological products without compromising their efficacy. At normal temperature, the dehydrated materials can be kept for years without losing any of their original properties.
The material that has been freeze-dried can be packaged and carried in tiny containers; no forward refrigeration is required.
Products that have been freeze-dried do not contain bacteria or enzyme activity, and proteins do not coagulate.
Using a high vacuum during the drying and sealing process totally prevents oxidation of various components, including vaccinations and hemoglobin.
WORKINGS OF A FREEZE DRYER:
A drying chamber or manifold that is used to connect or hold the containers containing the samples that have already been frozen.
A low-temperature condenser to capture moisture vapor and direct non-condensable vapors to the pump for atmospheric release.
SALIENT FEATURES:
Freeze dryer of the Bench Top type.
The inner chamber is composed of non-magnetic stainless steel, while the outer chamber is built of appropriately powder-coated CRC sheet.
Complete with a see-through Perspex lid.
To reduce heat loss, high-grade PUF is insulated between the inner and exterior chambers.
Mounted on swivel casters, it is housed in a superstructure steel frame.
The top panel and condenser (COLD TRAP) are made of stainless steel (SS-304 grade).
Copper refrigeration coils that are bonded to the externally insulated condenser.
Long service life, good efficiency, and low noise compressor.
Adheres to worldwide green environment requirements.
A pre-freeze feature is present in the big opening condenser.
A clear drying chamber that is safe and easy to use.
Low volume,
TECHNICAL DETAILS:
System Type Microprocessor-controlled system with fully automatic operation
Ice Condenser Capacity Holds 8 liters of ice
Display 7-inch LCD touchscreen with graphical representation of temperature and vacuum trends
Monitoring Automatic event recording for continuous monitoring
Operation Modes Supports both automatic and manual operation
Ice Performance Capacity Capable of freezing 5 liters per day
Lowest Condenser Temperature Reaches a temperature of -85°C
High Ambient Performance Designed to maintain condenser temperature efficiently, even under high ambient conditions
Ice Condenser Chamber Constructed from stainless steel 304/316 with PTFE coating for chemical resistance
Refrigeration System Energy-efficient, CFC/HCFC-free system with a high-performance 1 HP compressor
Vacuum Pump Safety Pump activation is sensor-controlled, starting only after the condenser reaches -40°C to prevent moisture or liquid entry in auto mode
Alarm History Records alarm malfunctions for tracking and analysis
System Safety Password-protected feature to prevent mishandling
Alarm System Audible and visual alarms for all events during the process
Process Display Displays drying process and lead time for maintenance and service
Monitoring Automatic event recording for process monitoring
Vacuum Protection Vacuum break valve to prevent oil back streaming into the pump
Parameter Unit Convertible units for user convenience
Defrosting Hot gas defrost function for easy chamber cleaning
Drain System Drain valve provided for disposal of defrost materials
Condenser Coil Placement Located inside the chamber for enhanced performance
External Dimensions 825 × 775 × 860 mm (W × D × H)
Voltage Protection Line voltage display for monitoring high/low voltage to protect the machine
Vacuum Pump Maintenance Usage time tracking for timely servicing
Product Shelf Inside the drying chamber is a three-tiered stainless steel shelf for vials, microtiter plates, and tiny tubes.
Drying Chamber PTFE-coated stainless steel 304, 16 ports with independently operated rubber valves for microtiter plates, flasks, and ampoules, and an acrylic top cover for observation
Accessories Includes clamps, connecting pipes, exhaust filters, and other required fittings.
Vacuum Pump Rotary vane double-stage vacuum pump with 140 L/min displacement, ultimate vacuum pressure of 2 × 10⁻³ mbar, anti-suck-back protection, noise level of 49 dB, nominal rotational speed of 1470 rpm, water vapor tolerance of 60 mbar, continuous inlet pressure of 1013 mbar
Ampoule Adapter Ampoule adapters that correspond to the drying chamber’s port count
Flask Set Six round-bottom wide-mouth flasks with caps (300 ml and 500 ml, three each)
Flask Adapter Set of 18 adapters for attaching flasks
Ampoule Set One packet each of 2 ml, 5 ml, and 10 ml ampoules
Vacuum Consumables One container of vacuum grease and 3 liters of vacuum oil are included.
Reviews