FUME HOODS
Make Dinesh Scientific
DESCRIPTION
The purpose of the laboratory fume hoods with cabinets is to offer a safe and regulated environment for handling hazardous materials and conducting experiments in laboratory settings. These fume hoods provide scientists and researchers with a complete solution because they have an integrated cupboard and an enclosed workspace.
The fume hood itself is made of premium materials and usually has a surface that is resistant to chemicals and long-lasting. The sash, which is vertically adjustable, keeps potentially dangerous vapors and fumes contained while facilitating simple access to the interior. By diverting harmful materials away from the user and into the ventilation system, the integrated airflow system makes sure that they are effectively removed.
APPLICATION:
- Hood for the General Chemical Fume Section
DESIGN BASIS:
- Observe ASHRAE-110 requirements regarding face velocity.
FUME HOOD STRUCTURE:
- Floor-mounted aerodynamic device.
AIR FLOW TYPE:
- Low Continuous Volume Type of Exhaust
NOISE LEVEL (AT MAIN BODY):
- Sound levels of less than 65 dB (the blower will be installed on a remote mounting kit)
CONSTRUCTION:
- Having two skin tones
STRUCTURE OUTER SKIN (MOC):
- CRC Sheet Duly Powder Coated (PCCRC). Outer Panel sheet 18 SWG and structure frame 18 SWG & 20 SWG sheet.
WORK TOP:
- Our worktops are traditionally constructed from thick DISHED CORED from a variety of MOC options, and they are even thicker at the MARINE EDGES to prevent spills and unintentional damage. Chemical resistance, splash proof, and spill proof Granite/SS-304 worktop that must be skirted from all sides to prevent chemical spills (per customer requirement).
CUP SINK:
- PP/Porcelain sink designed to gather chemical waste on the worktop.
INNER CHAMBER VERTICAL LINER:
- Heat and Chemical Resistance, Smooth-finish, fire-resistant, easily cleanable, panel composed of PRL integral work (6mm thick).
EPOXY POWDER COATING:
- epoxy colors that are extremely resistant to chemicals powder coated.
BAFFLE:
- Fumes are instantly captured and removed or slid at a much faster speed thanks to the specially designed removable back baffle.
UTILITY VALVES:
- According to international standards, our valves have fine utility control, can withstand 200 PSI of pressure, and have brass fittings for gas connections. Water, compressed air, nitrogen, and vacuum all require one each.
SUCTION:
- Airflow is distributed more easily with the help of a three-point suction system (for light, normal, and heavy fumes) with a baffle and finely tuned horizontal slots.
AIRFOIL:
- Design of Aerodynamics, Made of SS 304, this horizontal fixed airfoil mounted on the worktop offers safe fume ventilation and spill retention with an ergonomic design.
OPTIONS:
- PP + FRP heavy duty blower housing that is highly resistant to chemicals, complete with a P.P. blower and heavy duty motor. An additional cost is the M.S. painted blower housing.
- Per running foot, PVC ducting.
- Panel-mounted remote-controlled utility valve with an ergonomic nozzle for use in an air work chamber
- Panel-mounted remote controlled utility valve for water that has an ergonomic nozzle for use in a work chamber
- Panel-mounted remote-controlled utility valve with nozzle for ergonomic vacuum work chamber use
- Panel-mounted remote-controlled utility valve with nozzle for ergonomic operation in gas work chamber
- Modular epoxy scaffolding/lattice resistant to chemicals and acids.
TECHNICAL DETAILS:
MODEL |
DS-FH-7 |
SUPERSTRUCTURE OF FUME HOOD CONSISTS | |
Overall Dimension | Width 1800 x Depth 915 x Height 2300 |
Size of Fume Hood | Type of Hood: Low Constant Volume (LCV) Type Bench Fume hood |
Front posts | Aerodynamic shape in GI construction |
Inner Dimension | Width 1600 x Depth 645 x Height 1250 |
Structure frame | 2.0 mm thick GI construction |
Inner lining, rear baffles, top baffles | 6.0 mm thickness with coating of acid resistance phenolic resin. |
Outer panels | 1.2 mm thick GI construction |
Interior construction | Chemical and heat resistant, smooth finish, easily cleanable panels |
Cable manager | PVC cable manager to avoid cable dangling from equipment to sockets |
Airfoil | Flip-on type in Min. 1.6 mm or better thick SS – 316 construction |
Exhaust duct collar | Streamlined shaped in PP construction. |
Sash handle | Full-length handle in Aluminium construction |
Sash movement mechanism | Counterweight mechanism |
Vapor-proof tube lights | Twin (40 watts each) fitting with fluorescent lamps. |
Sash | Combination type, Frameless design in toughened glass construction |
Valve Location | Corner post on the left-hand side of the fume hood |
Flexible Tubing Length | 1.5 meters |
Body Construction | Forged brass |
Spindle Construction | Brass |
Knob Color Codes | Yellow (Air), Blue (Nitrogen), Green (Water) |
Flexible Tubing Material | PU-4 for compressed air, Nylon braided PVC Hose for water |
Nozzles | Angular shaped serrated nozzles |
Nozzle Construction | Epoxy coated forged brass construction |
End Fittings | Provided |
Knob Material | Plastic construction |
FUME HOOD WORKTOP | |
Sink Dimensions | 100 x 200 mm |
Countertop Material | Black color natural granite |
Thickness | 18 to 20 mm |
Raised Rails | On all four sides |
Sink Shape | Oval-shaped |
Drainage Type | For tap water |
Sink Construction | PP construction (Molded polypropylene) |
Drainage Location | Left/right side of the fume hood |
ELECTRICAL SERVICES WITH INTERNAL WIRING. | |
Light Switch | 5.0 A switch for light |
Socket with Switch | 5/15 A 3-pin Socket with switch (230 V, 6/16 A, 50 Hz) along with 8 nos. MCBs |
MCBs | 4 nos. of 5 A and 4 nos. of 15 A |
Fume Hood Under Structure | Fabricated out of heavy gauge rectangular shape hollow pipes in MS construction, duly finished with corrosion-resistant coatings |
BAFFLE DESIGN | |
Baffle type | Effective suction of light, medium, and heavy fumes is achieved with a three-point suction and fix-type baffle arrangement, with the baffle ensuring a smooth and prompt emission of fumes. |
FUME HOOD UNDER-CABINETS | |
Cabinets | Detachable design apparatus storage twin cabinets fabricated out of GI sheet |
Castors | Twin castors for easy removal of the cabinet |
Doors | Twin doors in double-wall construction |
Chemical Storage | Provided with two numbers of exhaust ports with rigid/flexible ducts connected to the exhaust passage of the fume hood |
Lining | FRP Lining in inside cabinet |
Handle | Flushed-type recessed handle |
Door Hinges | 110 º special design door hinges, Hinge cup/arm: nickel-plated steel |
Shelves | One fixed shelf |
Base Frame | Recessed base frame in heavy-duty GI construction |
Ventilation | Special arrangement for air ventilation inside the cabinet |
AIRFLOW MONITOR | |
Airflow Monitor | Digital display of face velocity in m/sec with on-screen display of visible airflow and audio alarm in low flow conditions |
Sensor | Integral airflow sensor |
Flow Control Valve | Provided to regulate airflow |
LED Indication | Red for low flow, Green for normal flow |
Calibration | Push-button calibration and configuration |
Alarm | Audio alarm in low flow conditions |
Power | Three-phase, 440-volt motor with a 2 HP, 2800 CFM output. The pump’s capacity allows fumes from the first floor to be vented through a 20-foot duct pipe line to the roof. |
FUME HOOD SASH | |
Toughened glass thickness | Toughened glass with a thickness of 5 mm, arranged in combination and rising vertical styles, and frameless design. The fume hood is operated by a multi-wire, flexible sash rope with a 316 stainless steel pulley and counterweight mechanism. |
Temperature sensor | Temperature sensors combined with temperature indicators.
LEDs used to continuously display the fume hood’s temperature. |
Duct damper | 200 mm diameter PP duct damper comes with an extended spindle that used with a motorized drive, manual operation handles, and one pre-drilled flange on each side. |
ADDITIONAL ACCESSORIES:
- Two cabinets (2 X 2 X 1) (W X D X H) feet that are mounted on the wall.