BIO SAFETY CABINET
MAKE DINESH SCIENTIFIC
DESCRIPTION:
A specialized piece of lab equipment called a biosafety cabinet (BSC) is made to offer a controlled atmosphere for handling hazardous compounds, especially biological agents that could endanger the worker, the surrounding area, or the samples they are handling. Maintaining the integrity of pathogen-related investigations and safeguarding researcher safety depend on the use of biosafety cabinets.
FEATURES:
- A canopy exhaust connection allows the Type A2 cabinet’s HEPA-filtered exhaust air either vented outside or back into the space.
- A fraction of mixed downflow and inflow air from a same plenum is known as HEPA-filtered downflow air.
- All biologically contaminated ducts and plenums have negative pressure air surrounding them. The work area is protected from the negative pressure by double wall plenums.
- High efficiency particulate air (HEPA) filters, which are incredibly effective, are passed via air drawn through a pre-filter. The HEPA filter’s lifespan is significantly increased by the installed prefilter. Equipped with a HEPA filter, it complies with EU -14 Grade regulations and has an efficiency rating of
- Over 99.995% for 0.3 μ. The filter is composed of imported micro fine glass fiber media that is fire retardant and water resistant. Higher air flow volumes are accommodated by the design of these filters.
- Prefilters with an efficiency of down to 10 microns are made of non-woven synthetic material, complying with EU – 4 / G–4 Grade, and featuring HDPE mesh and Al expanded mesh on the air-leaving side. It is possible to clean these filters.
- Placed atop a robust tubular stand featuring retractable castors.
- Aerodynamic airflow grills guard against obstructions and ensure safety.
- Available with UV and fluorescent interlock
PROTECTION OF THE CASS II BIOSAFETY CABINET:
- Particulate matter is dispersed throughout the chamber by high-velocity jet nozzles that introduce filtered air into it. High-velocity air is blasted through HEPA filters.
- The contaminated air is drawn in by the lower part of the air showers and then passes through a pre-filter placed at the base to reach the blower supply plenum.
- This is a continuous process that keeps the air inside the chamber filtered and recirculated without any interaction with the outside world.
FRONT AND UPPER COVER:
- Maintenance and replacement of the filter, blower, and front control panel are made easy by the removable top and front covers.
MATERIAL OF CONSTRUCTION:
- The material of the working table is stainless steel (SS-304). The external cabinet is made of stainless steel (SS-304) OR properly powder-coated CRC sheet (as requested).
FRONT SASH/WINDOW:
- For a clear view of the interior, the front sash is made of toughened transparent glass. Furthermore, it offers the best resistance and protection against dangerous UV rays, shielding the wearer from UV radiation exposure.
VALVE-FITTED DRAIN TROUGH:
- If there are any liquid spills, they may be easily cleaned up and disposed of in the base trough.
UV LAMP DECONTAMINATION:
- The motor blower and UV light, which emit UV rays with a wavelength of 253.7 nanometers, are interlocked, and they turn on and off in tandem with the opening and closing of the front sash. A timer (Option) is used by UV lights to regulate the decontamination cycle and extend their lifespan. After the predetermined amount of time for decontamination has passed, the UV lamp turns off and turns the fluorescent lamp ON.
SPLASH PROOF POWER SOURCE SOCKET:
- When using tiny electrical devices inside the cabinet, splash-proof outlets are provided for comfort.
GRID FOR FRONT AIRFLOW INTAKE:
- Potential turbulence and pollution are eliminated by the aerodynamically built front airflow intake grid.
CASTOR WHEELS AND FLOOR STAND:
- The Floor Stand is constructed from sturdy tubular pipe that has been properly powder coated. It also has robust castor wheels that rotate and a complete brake system on the front wheels.
TECHNICAL DETAILS:
MODEL |
DS-BC-3x2x2 |
Purpose | Biological safety cabinets are designed to carefully control ventilation in order to keep the specimen in a controlled environment and to sweep airborne particles created during routine microbiological processes away from the user. |
Type of air cleanliness class limits (air quality) in the working area | 1 and 2 (Class 100) |
Type of Configuration | Freestanding |
Direction of air flow | Vertical |
Pressure Monitoring System with pressure drop | 13-14 mm Hg pre fiber |
Nominal inflow velocity in feet per min with air volume @450 cube feet/min | 90 |
Nominal down flow velocity in feet per min | 45 |
Noise level in dB | 65 |
Type of air flow pattern | 70% air recirculated through filter 30% air exhausted |
Type of Sterilization used in the cabinet | UV Germicidal tube |
Filtration efficiency of HEPA filter | 99.99% for 0.3-micron particles |
Material used for the cabinet area | Stainless steel 304 grade |
Type of filter used for air supply and exhaust | Ultra-Low Particulate Air (ULPA) and High Efficiency Particulate Air (HEPA) |
Type of illumination used for working surface | In addition to white light, UV tube lights with optical reflectors guarantee uniform UV radiation distribution throughout the cabinet. |
Intensity of light in lux | ≥ 600 |
Material used for working area | Stainless steel 304 grade |
Pre filter provided | Yes |
Width of the working area in feet | 3ft |
Filtration efficiency of ULPA filter | 99.999% for 0.1-micron particles |
Opening height of the sash (door) in mm (Put 0 if not applicable) | 200 |
Type of power supply in VAC, Hz | 230V ± 10V, 50Hz |
Depth of the working area in feet | 2ft |
Height of the working area in feet | 2ft |
Type of Display | LCD |
Front door | Transparent, 5 mm thick, hardened SLD door |
Control system for the choice of timed UV exposure provided | Yes |
Automatic airflow provided | Yes |
Casing | Epoxy coated CRCA frame |
UV Lamp provided | With separate switch |
Microprocessor control of air velocities in real time with display provided | Yes |
The exposure time of UV light controlled through timer (in mins) | 10 |
Auto speed increase on the opening door for maintaining velocity | Yes |
Castors provided | Yes |
Bio saftey cabimet Provision for fitting taps | Vacuum, water, and non-flammable gas taps |
Locking facility provided | Yes |
Corrosion proof interior design and easy clean | Yes |
Drain outlet with flexible hose | Yes |
Leveling jacks provided | Yes |
The time range controlled by the control system for the choice of timed UV exposure (in mins) | 5-10 |
Biosafety cabinet smooth interior and exterior | Yes |
Audio and visual alarms for HEPA filter failure | Yes |
Gas burner | 1 |
Hepafilter | 1 |
Number of UV Lamp | 1 |
ADDITIONAL | |
Class | II Type B2 |
Height Stand | Included |
Arm Rest | One set of detachable arm rest |
Electrical Outlet | One electrical outlet |
Sash Opening | 8-inch sash opening; UV-absorbing front glass |
Ventilation Exhaust Air Volume | 665 CFM |
Motors | Brushless DC motors for automated adjustment of airflow |
HEPA Filter | Class H |
UV Category | High UV-C radiance G30T8 at 254 nm |
UV Exposure Time | Programmable from 0 to 100 hours |
Front of Cabinet | Angled 10° to minimize glare |
Cabinet LCD Indicator | Shows inflow and the wrong window position |
Automatic Operation | For UV and blower |
Cabinet Testing | Variables such as supply and exhaust, noise level, vibration, downflow and inflow velocities, and light intensity Data from HEPA leak tests |
Cabinet Setup | Contains all sheds, ducting outlets, blowers, and filters. |
Servo Stabilizer | 5.0 KVA is offered to prevent voltage fluctuations for stable operation. |
Reviews