BOD INCUBATOR
MAKE DINESH SCIENTIFIC
MODEL DS-BOD-1100
DESCRIPTION
An incubator for biological oxygen demand, or BOD for short, is a specialized piece of scientific equipment used to quantify and incubate biological oxygen demand in water samples under carefully regulated circumstances. A critical metric for determining the degree of organic contamination in water is BOD. A BOD incubator is described as follows in general:
BOD incubators are essential for doing experiments like figuring out the oxygen demand of organic matter in water samples or growing bacteria for various purposes. They are typically employed in environmental and biological research. These incubators have airtight rooms to keep out contaminants and let researchers change the conditions to suit their own needs.
TEMPERATURE CONTROL:
Precise temperature control mechanisms are incorporated into BOD incubators to uphold a steady and regulated atmosphere.
The usual temperature range for BOD testing is 20 to 25 degrees Celsius, which is the typical range.
HUMIDITY CONTROL:
In order to keep the sample from evaporating throughout the incubation period, certain models could also include humidity control.
TECHNICAL DETAILS:
MODEL DS-BOD-1100
Volume 1100 liters
Lighting System Linear LED lights horizontally mounted on each shelf, total of 4 shelves
Temperature Range 5°C to 44°C (+0.5°C Light ON at all temperatures)
Temperature Accuracy ±0.5°C across all set temperatures
External Dimensions Not exceeding 2 m × 90 cm × 100 cm
Light Intensity Programmable from 10% to 100%, dimmable 100 µmoles/m²/s, measured at 6″ from lamp bank
PAR Light Spectrum Available
Refrigeration System Top-mounted for easy maintenance (e.g., cleaning)
Growing Area & Height Work area of 2.5 m², plant growth height of 28-35 cm per shelf, shelves in 14″ increments
Temperature Safety Alarm Controller shuts down the chamber and restarts automatically when temperature returns to normal
Door Single door with full access to chamber interior, equipped with a magnetic gasket
Cooling System Air-cooled condensing unit with hot gas bypass system for bypass-based heating (no heater-based heating) and continuous compressor running.
Display Features Graphic display of actual and set values, view program steps, and sequence time duration
Dual Experiment Protection Integrated yet independent temperature limit shutdown
Additional Features One access port/fresh airport, floor drain, caster assembly, and leveling legs
Material Side walls: 26-gauge stainless steel; Floor: 24-gauge #304-4 stainless steel
Interior Coating Epoxy white coating for improved light reflection
Future Upgrade Capability Provision for future CO₂ addition and scrubbing
Voltage Stabilizer Provided with the growth chamber
Program Configuration Supports manual, real-time, or elapsed time operation
Programming Features Continuous, diurnal, and multi-step program capability
Program Storage Multiple program storage with multi-step functionality
Calibration Offset Two calibration offsets provided
Light Maintenance Alarm Audio and visual alarm for light lifetime maintenance
Controller Safety & Security Four-level protection for secure operation
Humidity Control Includes dehumidifier to enable RH range of 40-80%
Diagnostics & Troubleshooting Onboard diagnostics for troubleshooting
Temperature Alarm Alarms for low and high temperature deviations are audible and visible.
Ambient Temperature Monitoring Available
Reviews
There are no reviews yet.