AUTOCLAVE
MAKE DINESH SCIENTIFIC MODEL DS-AC-120
PRODUCT DESCRIPTION
We bring forth an elaborate range of Horizontal Autoclaves, which is offered at industry leading rates. These products are widely used in various laboratories for their day to day studies on scale sterilization procedures where utmost significance is laid on the dryness of the sterilized medium. This range of products is manufactured in exact accordance with the preference and requirements of the clients.
SAILENT FEATURES:
- Dimensional accuracy
- Trouble free operation
- Longevity
- Cylindrical / Rectangular design.
- Stainless steel interior and exterior.
- ISI marked flange / immersion heating elements.
- Working pressure 15 psi to 20 psi.
- Standard temperature 121°C.
- Silicon rubber door gasket.
- Digital Temperature controller.
- Digital Timer and alarm (buzzer)
SCOPE OF APPLICATION:
They are specifically used to decontaminate biological waste and sterilize media, and instruments. In medical labs, autoclaves are used to sterilize medical equipment, glassware, surgical equipment, and medical wastes.
SAFETY:
- The autoclave automatically cut off the heater & cycle in case of Low water level
- The Autoclave an electronic safety switch that would not allow cycle to run if door is not locked properly.
- Autoclave pressure-interlock and cannot be opened when chamber is under pressure. The Autoclave fitted with a CE certified spring loaded safety valve for over-pressure and independent thermal cut off in case of over temperature.
- The Autoclave drain valve for cleaning or changing with fresh water.
- The autoclave safety for Over temperature, Electrical overload.
- The electrical safety ensured by inbuilt MCB.
TECHNICAL DATA:
PARAMETER | VALUE |
Volume/Capacity (in Litre) | 110 -120 litre |
Dimension of Working Chamber | Dimension of working chamber- as per requirement for Capacity. |
Material of Construction | · External Structure of MS Sheet duly heat cured epoxy coated of better grade SS.
· Door Ring & rest SS304. · All wetted parts like Working Chamber, Jacket, Door. |
Temperature Range & resolution | · Temp. 130°C , Resolution: 0.1°C, Operating Temperature : 121°C.
· Autoclave customizable sterilization temperature setting 121°C in steps of 0.1°C |
Design/ Type of Sterilizer | · Steriliser insulated with Glass wool with leak proof Silicon door gasket (expansion type) with rectangular outer body.
· Fully Automatic Vertical Cylindrical top loading Steam. · The autoclave fitted with 4 castors for easy manoeuvrability & placement. |
Automatic Purging cum
Vacuum Breaker & exhaust of Steam |
· The Autoclave lid cover provided with auto purge.
· The unit a solenoid valve for additionally purging the air & normal exhaust. · The complete cycle automatic – purging, · Cum vacuum breaker valve and a manually operable valve for exhaust. · sterilizing, exhaust of steam – fully automatic |
Steam supply to Sterilizer | Built in immersion type chamber heater for steam generation with water level protection system & alarm made of SS 304 |
During cycle | · During cycle operation
· The programmable logic controller controller display readings of the three temperature sensors. · Pressure (in mbar/Psi/Kpa), temperature set point and remaining time |
Lock | Manual Lock; Autoclave Single lever door locking system for easy and convenient opening & closing with long handle for Lid. |
Type & no. of Door of Door | Hinged Type Single Door. |
Power | · 230 VAC.
· 50 Hz. · Single phase. · MCB with suitable capacity & rating heater power. |
Alarm & Alerts | · The Autoclave audible and visual alarm / alert upon cycle interruption or completion Audio visual alarm for Low water level
· Alarm for Over Temperature. · Audio Visual alarm for Sensor Open and over pressure. |
Controlling system | Automatic: Programmable Logical controller advanced technology controller Controlled with preselected Sterilization variable programs requirements. |
Timer | · The timer range min. 1 minute to 99 minutes.
· The sterilization hold time adjustable in steps of 1 minute. |
Type of Interface to specify parameters for
running Sterilization cycle |
Keyboard interface |
Heater Power | Min. 3.5 kW capacity requirements to run the sterilization process smoothly |
Accuracy | Max. ± 10C |
Pressure Gauge | · 0-30 psi , operating pressure: 15-16 psi.
· The Autoclave a stainless steel pressure gauge with dual range dial display in KPA and PSI along with a correlated temperature scale for steam in °C |
Temperature Sensors | The Autoclave 3 nos. of pt100 temperature sensors |
Documentation
Features for audit trail |
· Print facility for record generation of dates
· time · load · Identification number and operating parameters for real time printing of temperature sensors along with Fo Summation plus pressure channel. |
Controller & Display | · Accurate temperature control with Programmable logic controller advanced technology controller for setting the sterilization parameters with Start / Stop Key.
· Key for setting Sterilization Temperature & Time and Date & time & other sterilization process related parameters. |
Alarm | · Chamber Temperature, Batch Number
· The controller display all process related parameters real-time & allows setting /Customization of cycle related parameters Temperature, Timer. · Time and Date, Alarm Indicator · Low Water Indicator. |
Carrier/Basket | Supply with min. two (02) nos. Basket or sterilization carrier of suitable sizes made of SS 304 |
Print facility for record generation of dates, time,
load, identification number and operating parameters |
· The Autoclave facility of connecting an external printer which print real-time details of customer name, batch number.
· Date, time, temperature set-point, readings of three temperature sensors · Pressure channel, Fo summation and other process related information. |
ACCESSORIES:
- supplied with all other accessories required to put the system functional
- Suitable printer for printing facility
- Suitable Voltage stabilizer
- Additional two Basket or sterilization carrier suitable sizes made of SS 304