Spectrophotometer
Make Dinesh Scientific Model DS-SPM-845
Product Description
We M/s Dinesh Scientific are a leading Manufacturer of Nano Spectrophotomter, Double Beam Microprocessor UV/VIS Spectrophotometer, Advance Single Beam Microprocessor UV-VIS Spectrophoto- meter, Touch Screen Double Beam UV-VIS Spectrophotometer, Visible Spectrophotoeter and Fluorescence Spectrophotomter from Ambala, India.
Features
- Low on maintenance
- Smooth functioning
- Ease of usage
SPECIFICATIONS:
Model No | DS-SPM-845 |
Parameters | Values |
Light Source | Xenon Flash |
Diffraction Grating (lines/mm) | 1200 |
Switching of Light Source | NA |
Wavelength Setting And Scanning | Automatic |
Type of Spectrophotometer | UV – VISIBLE |
Type of Optical System | Double Beam |
Monochromator Type | Czerny-turner |
Detector Type | Photodiode |
Spectral Bandwidth Type | Fixed Bandwidth |
Source Wavelength – Minimum | 190 nanometer |
Source Wavelength – Maximum | 1100 nanometer |
Resolution | 1 nanometer |
Wavelength Accuracy (+/-) | 0.5 nanometer |
Bandwidth (nm) | 1 |
If variable band width, Specify the incremental step value(mm) | NA |
Scanning Speed (nm/min) | 5000 |
Focal length (mm) | 250 to 299 |
Photometric measurement modes | Transmittance,Absorbance,Concentration (Wavelength, time),Reflectance |
Photometric Absorbance (Max) (Abs) (+/-) | 3.5 |
Photometric Absorbance Accuracy (Max) (+/-) | 0.004 |
Photometric Transmittance (Max) (+/-) | 100 percent |
Photometric Transmittance Accuracy (Max) (+/-) | 0.5 percent |
Photometric Reflectance (Max) (+/-) | 100 percent |
Photometric Reflectance Accuracy (Max) (+/-) | 0 percent |
Stray Light Correction | N/A |
Baseline Correction | Automatic |
Display | Through PC |
Display type | NA |
Display Size | 0 inch |
Test result printing | Through external printer |
If inbuilt printer, Type of printer | N/A |
Suitable software for connecting PC & Printer | Yes |
Connectivity | N/A |
Internal storage(GB) | 0 |
Sample switching/selection | Manual |
Capacity of Sample holder / Sample Carousel | 2 |
Mximum Path Length of sample | 100 millimeter |
Number of Cuvettes supplied-inclusive in the scope of supply | 2 |
Power Supply | 230 V ± 10, 50 Hz |
Any other features/accesories covered in scope of supply | NA |
Spares and Consumables inclusive in the scope of supply | No |
List of Items and Quantity of each item included in the offer | Cuvettes /System |
Minimum Operating Temperature | 10 degree Celsius |
Maximum Operating Temperature | 35 degree Celsius |
Operating Humidity (RH) (%) at 40 degree C | 80 percent |
Availability of Spares (at extra cost) | 10 year |
Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use General requirements | Yes |
Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use | Yes |